INSTALLATION & OPERATING INSTRUCTIONS
Modern FullView DV Gas Fireplace Insert Heater
Cosmetically Incredible & Highly Efficient at 84.1% Steady State Efficiency
MODEL NO. FV33-M-1111
INSTALLER: Leave this manual with the appliance.
CONSUMER: Retain this manual for future reference.
INSTALLATEUR : Laissez cette notice avec l’appareil.
CONSOMMATEUR : Conservez cette notice pour consulta-
tion ultérieure.
WARNING: If the information in this manual is not followed
exactly, a fire or explosion may result causing property dam-
age, personal injury or loss of life.
Do not store or use gasoline or other flammable
vapors and liquids in the vicinity of this or any
other appliance.
WHAT TO DO IF YOU SMELL GAS
Open windows.
Do not touch electrical switches.
Do not try to light any appliance.
Extinguish any open flame.
Do not use the phone in your building.
Immediately call your gas supplier from a neighbor's
phone. Follow the gas supplier’s instructions.
If you cannot reach your gas supplier, call the fire
department.
Installation and service must be performed by a
qualified installer, service agency or the gas suppli-
er.
WARNING
Do NOT use this appliance if any part has been under water.
Immediately call a qualified service technician to inspect the
appliance and to replace any part of the control system and
any gas control, which has been under water.
AVERTISSEMENT : Assurez-vous de bien suivre
les instructions donné dans cette notice pour réduire au min-
imum le risque d’incendie ou pour éviter tout dommage
matéeriel, toute blessure ou la mort.
Ne pas entreposer ni utiliser d'essence ni d'autres vape-
rurs ou liquides inflammables dans le voisinage de cet
appareil ou de tout autre appareil.
QUE FAIRE SI VOUS SENTEZ UNE ODEUR
DE GAZ:
Ne pas tenter d'allumer d'appareil.
Ne touchez à aucun interrupteur. Ne pas vous servir
des téléphones se trouvant dans le batiment où vous
vous trouvez.
Appelez immédiatement votre fournisseur de gaz depuis
un voisin. Suivez les instructions du fournisseur.
Si vous ne pouvez rejoindre le fournisseur de gaz, appe-
lez le service dos incendies.
L'installation et service doit être exécuté par un quali-
fié installer, agence de service ou le fournisseur de gaz.
Vue de la page 0
1 2 3 4 5 6 ... 47 48

Résumé du contenu

Page 1

INSTALLATION & OPERATING INSTRUCTIONS Modern FullView DV Gas Fireplace Insert Heater Cosmetically Incredible & Highly Efficient at 84.1

Page 2

9 GENERAL INFORMATION Your Mendota Gas Fireplace Insert has a state-of-the-art direct vent, sealed combustion system. This advanced, highly effici

Page 3

10 RIGHT SIDE & BACK PANEL VIEWLEFT SIDE & BACK PANEL VIEWFV33i EXTERNAL FEATURES-IDENTIFICATION DIAGRAMS-LIGHT DIMMERCABLE HOLEAC POWERCORD

Page 4 - INITIAL STARTUP ADVICE

11 FV33-M OVERALL DIMENSIONS 5 1/2291.25015 5/8Surround Faceto Gas LineEntry Hole Center11 7/8To Gas LineEntry Hole Center7 7/81 7/8SURROUND/FACEPL

Page 5

12 8.016" MIN.FROM GLASS FRAME EDGETO PERPENDICULAR SIDE WALL-A-12" MINFROM TOP EDGE OF TOPCONVECTION AIR OPENINGTO BOTTOM OF 8" DEEP

Page 6 - SPECIFICATIONS

13 INSTALLATION INSTRUCTIONS CAUTION: Each installation must conform to all local, state and national codes. Refer to the national fuel gas code an

Page 7

14 FLUE VENTING The FV33-M Insert must be vented vertically to the outside and must use the Mendota Co-Linear flexible ducting system. The minimum ve

Page 8

15 Chimney Flashing and cap (See FIGURE BELOW) The vent kits include a trim-able flashing. Measure, trim and shape flashing to fit the existing flue

Page 9 - ...CAUTION

16 14. Remove the Vent Adapter by removing two 5/16” Hex Bolts and sliding Vent Adapter towards rear of Insert. 15. Tightly secure 3” and 4” flex

Page 10

17 18. You are now ready to hook up the Insert to gas supply. Be sure gas plumbing instructions and all state and local codes have been carefully

Page 11 - -IDENTIFICATION DIAGRAMS

18 RAISED HEARTH SPECIFICATIONS In most installations, a 16" non-combustible protector is required in front of the unit’s glass door surfac

Page 12 - FV33-M OVERALL DIMENSIONS

1 In the Commonwealth of Massachusetts: • Installation must be performed by a licensed plumber or gas fitter; • A CO detector shall be installed in

Page 13 - CONVECTION AIR OPENING

19 GAS SUPPLY REQUIREMENTS NOTE: IF INSERT IS TO BE OPERATED WITH LP GAS, SEE PAGE 34 BEFORE PROCEEDING. CORRECT GAS PRESSURE AND PROPER GAS SUPPL

Page 14 - INSTALLATION INSTRUCTIONS

20 GAS PRESSURE REQUIREMENTS One major cause of operating problems with gas appliances can be improper gas pressure! Such problems as changes in flam

Page 15 - FLUE VENTING

21 HIGH ALTITUDE INSTALLATIONS For installations from 610-1370 meters (2000-4500 ft.) the orifice sizes (DMS) for natural gas is #43 and for propan

Page 16 - Chimney Flashing and cap

22 INSTALLATION CHECK OFF LIST The following check list must be completed prior to initial lighting of the Fireplace Insert, or manufacturer's

Page 17

23 2.) PULL3.) ROTATE4.) RELEASE1.) INSERTDOOR REMOVAL AND REPLACEMENT CAUTION: Do not operate the appliance with glass removed, cracked or broken

Page 18 - ...IMPORTANT

24 FV33-M BURNER MEDIA INSTALLATION INSTRUCTIONS WARNING: Failure to position the parts in accordance with these diagrams or failure to use only part

Page 19

25 BEFORE YOU BEGIN Read this entire manual before you use your new fireplace (especially the section “Safety Precautions” on page 7). Failure to fo

Page 20 - NAT. L.P. NAT. L.P

26 75 REMOTE TRANSMITTER OPERATING INSTRUCTIONS TO TURN ON THE APPLIANCE: 1. Press the ON/OFF button. The transmitter display will show all active

Page 21

27 MANUAL BYPASS OF THE REMOTE SYSTEM If the remote transmitter is misplaced or lost, the appliance can be turned on manually by sliding the three p

Page 22

28 “FIRST TIME” PILOT LIGHTING INSTRUCTIONS IMPORTANT: Be sure all items on "INSTALLATION CHECK OFF LIST" in the Installation Manual have

Page 23

2 and materials for servicing and proper operation. Due to high temperature, the appliance should be LOCATED out of traffic areas and away from furn

Page 24 - SLOT IN BASEPLATE

29 ATTENTION! The transmitter and receiver are RADIO FREQUENCY DEVICES. Placing the receiver in or near metal may severely reduce the signal range.

Page 25 - AIR SHUTTER ADJUSTMENTS

30 FV33-M GAS IGNITION SYSTEM WIRING DIAGRAM The appliance must be electrically connected and grounded in accordance with local codes or, in the

Page 26 - ON SMART

31 MAINTENANCE 1. ANNUAL MAINTENANCE OF MENDOTA UNITS IS REQUIRED. The following procedures must be performed each year by a Mendota ap-proved serv

Page 27

32 This conversion kit shall be installed by a qualified service agency in accordance with the manufacturer’s instructions and all applicable codes a

Page 28

33 5. Remove the Burner Airbox and Burner. 6. To remove Airbox, remove four screws along back edge of Airbox and lift Airbox out of firebox. 7.

Page 29 - LIGHT ON/OFF SWITCH

34 10. Loosen Pilot Light’s hex shape base using a ½” open end wrench. Rotate counter clock-wise ¼ turn to loosen. 11. Pilot arrives from the facto

Page 30

35 You must remove the left side Valve Access Panel to replace the pressure regulator. 16. Remove the left-side access panel mounted to the left ou

Page 31

36 LP PRESSURE REGULATOR CONVERSION INSTRUCTIONS WARNING: Failure to position the parts in accordance with these diagrams or failure to use only par

Page 32 - FLAME SENSOR

37 LP GAS PRESSURE REQUIREMENTS Inlet and manifold gas pressure checking taps are located on gas valve. These ports are only accessible from the oute

Page 33

38 WARNING DO NOT PROCEED WITH OPERATION OF THIS FIREPLACE UNLESS BURNER "CYCLES" ON/OFF WITHOUT DELAYS! CHECKING FOR NORMAL BURNER (S) IG

Page 34

3 FV33-M FEATURES - QUICK REFERENCE INFORMATION EXTERNAL DIMENSIONS: 30-3/8” Wide X 18-3/8” High X 15-3/4” Deep GLASS SIZE: NeoCeram Glass with non

Page 35

39 CUSTOMER INFORMATION AND TROUBLE-SHOOTING MAXIMUM ALLOWABLE SURFACE TEMPERATURE Mendota Inserts/Fireplaces comply with UL Standards for maximum su

Page 36 - REGULATOR

40 BURNER FLAMES ADJUSTMENT- AIR INTAKE DAMPER CONTROLS This appliance is equipped with two Air Intake Adjustment Damper Controls: PRIMARY DAMPER and

Page 37

41 BURNERS AIR SHUTTER CONTROLS During the initial installation, the Front Burner Rotary Manual Air shutter opening should be checked to make certa

Page 38 - 1" MIN

42 GAS VALVE TRAIN ASSEMBLY REPLACEMENT PARTS LIST FV33-M VALVE ASSEMBLY COMPONENTS LIST KEY# QTY Part Number Description 1 1 05-02-00344 885 PROFLA

Page 39

43 USE LARGE PLIERS TOBEND DOWN (4) TABSAS SHOWNGLASSGASKETGLASS FRAME ASSEMBLY REPAIR AND REPLACEMENT TO REPLACE DAMAGED GLASS 1. Bend Glass Ret

Page 40

44 MENDOTA WARRANTY QUALIFICATION & SERVICE REFERENCE FORM As a part of Mendota's on-going program of customer satisfaction, this Form ver

Page 41 - ADJUSTMENT

45 TAPE SHUT ------------------------------------------------------------------------------------------------------------------

Page 42

46 MENDOTA EXTENDED LIFETIME PROTECTION AND LIMITED WARRANTY MENDOTA GAS FIREPLACE INSERT MODEL: FV33-M NAT. & L.P. Mendota Division of John

Page 43

Johnson Gas Appliance Company 520 E Avenue N.W. - Cedar Rapids, IA 52405 Website: www.johnsongas.com or www.mendotahearth.com

Page 44 - AS SHOWN

4 TABLE OF CONTENTS SAFETY AND WARNING INFORMATION ...

Page 45

5 SPECIFICATIONS MODEL FV-33-M Natural Gas Propane Gas Input rating (Btu/hr) 0-610 m 25,000 25,000 Minimum input (Btu/hr) 0-610 m 13,500 20,8

Page 46

6 Specific Requirements for the Common Wealth of Massachusetts The information in this section applies to all installations performed in the Common W

Page 47 - MENDOTA GAS FIREPLACE INSERT

7 SAFETY AND WARNING INFORMATION READ and UNDERSTAND all instructions carefully before starting the appliance. FAILURE TO FOLLOW these instruc-tions

Page 48 - or www.mendotahearth.com

8 CONGRATULATIONS You are the owner of a world-class heat producing gas direct vent sealed combustion fireplace. This elegant, highly efficient Firep

Commentaires sur ces manuels

Pas de commentaire