FULLVIEW DIRECT VENT GAS FIREPLACE INSERT HEATER
Model FV-33i
HOME OWNER’S MANUAL
DOCUMENT NO. FV33i-PF2-OM-0812
In the Commonwealth of Massachusetts:
Installation must be performed by a licensed plumber or
gas fitter;
A CO detector shall be installed in the room where the
appliance is installed.
WARNING: Improper installation, adjustment, altera-
tion, service or maintenance can cause injury or prop-
erty damage. Refer to this manual. For assistance or
additional information consult a qualified installer, ser-
vice agency or the gas supplier.
CAUTION
THESE INSTRUCTIONS ARE TO REMAIN WITH
THE HOMEOWNER.
WARNING
If the information in this manual is not followed exactly, a
fire or explosion may result causing property damage,
personal injury or loss of life.
Do not store or use gasoline or other flammable
vapors and liquids in the vicinity of this or any
other appliance.
WHAT TO DO IF YOU SMELL GAS
Open windows.
Do not touch electrical switches.
Do not try to light any appliance.
Extinguish any open flame.
Do not use the phone in your building.
Immediately call your gas supplier from a neighbor's
phone. Follow the gas supplier’s instructions.
If you cannot reach your gas supplier, call the fire
department.
FOR YOUR SAFETY
A qualified installer, service agency, or the gas suppli-
er must perform installation and service.
Do not store or use gasoline or other flammable va-
pors and liquids in the vicinity of this or any other ap-
pliance.
WARNING
Do not operate this appliance with the glass removed,
cracked or broken. A licensed or qualified person
should do replacement of glass.
WARNING
Mendota gas fireplaces are heat producing appliances.
Do not burn wood, paper or other materials in this fire-
place. This fireplace is designed as a supplement
heat source. It is advisable to have an alternative pri-
mary heat supply.
WARNING
Do NOT use this appliance if any part has been under water.
Immediately call a qualified service technician to inspect the
appliance and to replace any part of the control system and
any gas control, which has been under water.
The installation must conform with local codes or, in
the absence of local codes, with the current National
Fuel Gas Code, ANSI Z223.1, or the current Natural
Gas and Propane Installation Code, CSA B149.1
Vue de la page 0
1 2 3 4 5 6 ... 15 16

Résumé du contenu

Page 1 - HOME OWNER’S MANUAL

FULLVIEW DIRECT VENT GAS FIREPLACE INSERT HEATER Model FV-33i HOME OWNER’S MANUAL DOCUMENT NO. FV33i-PF2-OM-0812

Page 2 - TableofContents

10 | Page 85-03-00891 ATTENTION! The transmitter and receiver are RADIO FREQUENCY DEVICES. Placing the receiver in or near metal may severely reduce

Page 3

11 | Page 85-03-00891 2.) PULL3.) ROTATE4.) RELEASE1.) INSERTDOOR REMOVAL AND REPLACEMENT CAUTION: Do not operate the appliance with glass removed,

Page 4

12 | Page 85-03-00891 BLOWER OPERATION AND WIRING WARNING: Live 120VAC Power must be connected to the junction box supplied on left side of this appl

Page 5 - ...CAUTION

13 | Page 85-03-00891 MENDOTA WARRANTY QUALIFICATION & SERVICE REFERENCE FORM As a part of Mendota's on-going program of customer satisfact

Page 6 - ON SMART

14 | Page 85-03-00891 TAPE SHUT ------------------------------------------------------------------------------------------------

Page 7

15 | Page 85-03-00891 MENDOTA EXTENDED PROTECTION AND LIMITED WARRANTY MENDOTA FV33 DIRECT VENT FIREPLACE INSERT Mendota Division of Johnson Gas App

Page 8

Johnson Gas Appliance Company 520 E Avenue N.W. - Cedar Rapids, IA 52405 Mendota Hearth Division W

Page 9 - ON/OFF KEY

2 | Page 85-03-00891 TableofContentsSAFETY AND WARNING INFORMATION ...

Page 10 - ATTENTION!

3 | Page 85-03-00891 SAFETY AND WARNING INFORMATION READ and UNDERSTAND all instructions carefully before starting the appliance. FAILURE TO FOLLOW t

Page 11 - SLOT IN BASEPLATE

4 | Page 85-03-00891 SPECIFICATIONS MODEL FV-33i Natural Gas Propane Gas Input rating (Btu/hr) 0-610 m 31,000 31,000 Minimum input (Btu/hr)

Page 12 - FV-33 BLOWER WIRING DIAGRAM

5 | Page 85-03-00891 CONGRATULATIONS You are the owner of a world-class heat producing gas direct vent sealed combustion fireplace insert. This elega

Page 13

6 | Page 85-03-00891 BEFORE YOU BEGIN Read this entire manual before you use your new fireplace insert(especially the section “Safety Precautions”).

Page 14

7 | Page 85-03-00891 REMOTE TRANSMITTER OPERATING INSTRUCTIONS TO TURN ON THE APPLIANCE: 1. Press the ON/OFF button. The transmitter display will

Page 15 - 85-03-00891

8 | Page 85-03-00891 TEMPERATURE INDICATOR (oF or oC) 1. Press the ON/OFF Key and Turn Off the Fireplace. 2. Simultaneously, Press both the MODE Key

Page 16

9 | Page 85-03-00891 “FIRST TIME” PILOT LIGHTING INSTRUCTIONS IMPORTANT: Be sure all items on "INSTALLATION CHECK OFF LIST" in the Install

Commentaires sur ces manuels

Pas de commentaire