B - 2 VERTICAL THROUGH-THE-ROOF VENTING USING
AN EXISTING "CLASS A" METAL CHIMNEY.
If you are replacing a wood stove you may use most existing "Class-A" metal chimneys as part of the venting system
for your Mendota DXV Stove. You must incorporate the special Dura-Vent Retro Adapter Kit into existing
chimney. The concept of the direct vent retrofitting is to mate the appropriate adapter to a section (cut to length) of
4-inch diameter aluminum flex pipe. This is then passed down through the center of the existing chimney system.
Three sizes of Adapters are available which should accommodate most sizes and makes of chimney systems. The
Retrofitting Connector (909B) is then attached to the bottom of the flex pipe. Both the Top Adapter, and the Retro-
fitting Connector are attached to the existing chimney with sheet metal screws. The stove is then connected to the
chimney with black direct vent pipe sections, including an adjustable length section.
1. After woodstove is removed, carefully sweep the existing chimney.
2. Position stove beneath existing vent system. Make sure the
clearances required are maintained.
3. Remove existing chimney cap. Measure the distance from the top
end of the chimney to the bottom of the ceiling support box, add 3"
to this measurement and cut a section of 4" flex pipe to that length.
4. Connect the end of flex pipe section to the under side of the
Adapter you have selected, using (3) #8 sheet metal screws.
5. Pass the flex pipe down through the center of the chimney system
and center the Adapter on the top of the chimney pipe. Drill (4)
1/8" diameter holes through the Adapter and into the chimney top.
Insure that you are in fact drilling into the metal on the chimney.
Twist lock the vertical top (0983) onto the Adapter.
1. Pull the flex pipe down through the chimney support box until it
protrudes approximately 3". Connect the flex pipe to the Retro
Connector by slipping it into the 4 3/4" diameter sleeve on the top
side of the Connector. Use (3) #8 sheet metal screws to assemble
these two parts.
2. Push the flex pipe back up into the ceiling support box, center the
Retro Connector and screw it into the support box with #8 sheet
metal screws furnished. The holes in the Retro Connector are pre-
punched.
3. The connection between the stove and the Retro Connector may be
completed with section of black direct vent pipe together with an
adjustable length.
IMPORTANT: Always use
Mendota approved direct vent
parts and vertical chimney caps.
B - 3 VERTICAL THROUGH-THE-ROOF VENTING
USING AN EXISTING MASONRY CHIMNEY.
A flexible vent kit is available for converting an existing masonry
chimney to venting a SDV Direct Vent Stove. The kit consists of a
heavy duty .010 aluminum flexible liner, masonry flashing, and a vent
cap assembly. The chimney liner kit is available in a 35 ft. Length.
Follow installation procedure in B-2 above.
IMPORTANT: Always use Mendota approved direct vent kit parts and vertical chimney caps when installing the
Mendota direct vent kits in class A and masonry chimneys. The vent kits are designed for exclusive use with Mendota Direct
Vent Stoves
.