INSTALLATION INSTRUCTIONS
The Mendota Stoves must be installed in accordance with local codes, if any, if not, follow the current edition of
ANSI.Z223.1 (US Installation) or CAN1-B149 (Canadian Installations). For mobile home installation, install per the
manufactured home construction and safety standard, title 24 CFR, part #3280 (U.S.) or CAN/CSA Z240 MH (Canada).
The SDV Stove must be installed by a qualified Mendota approved service person.
1. Carefully unpack the Stove. Inspect packaging for loose parts. You should find a trivet plate.
2. Position Stove in its final desired location [See Page 4]. Be sure to maintain minimum clearances to
combustibles. Check to be sure all venting restrictions and requirements are being followed (See Pg. 7-
16). Circulating room air enters the fan through the back of the pedestal. Carefully check to be certain
that nothing blocks air entry to this area. Lower front door must also be free to open easily for inspec-
tion and servicing of the burner system.
CAUTION: When the Stove is installed directly on carpeting, vinyl or other combustible material other
than wood flooring, the Stove MUST be installed on a metal or wood protection panel extending the
full width and depth of the Stove.
3. Remove front glass window/door by releasing the 4 turn latches behind side doors (rotate latches
counterclock-wise and pull outward) and carefully sliding glass door forward.
4. You are now ready to hook up the gas supply. Be sure gas plumbing instructions [page 16 & 17] and
all state and local codes are carefully followed.
5. Use approved flexible gas connection or rigid piping [depending on state & local codes] to attach
burner to gas supply. Be sure correct size IPT black iron gas supply line is used [See Table 1: Gas
Supply Line Sizing on page 16]. CAREFULLY CHECK FOR GAS LEAKS.
6. Connect gas supply line to 3/8" inlet nipple on the rear of the stove pedestal. (See FIGURE 6: Piping
Detail, page 16.)
7. To use the blower there must be a 115 Volt electricity source within 5' of Stove. (See Pg. 4 & Pg. 26)
IMPORTANT: Any safety screen, guard, glass, grill, pressure relief cap, etc. removed for servicing a
fireplace/room heater must be replaced prior to operating the fireplace/room heater.
BLOWER OPERATION
The Mendota SDV40 Stove is designed so the blower operates automatically when main burner is on and rheostat is “on”.
The blower output can be regulated with the rheostat (included). NOTE: There will be a time delay in blower operation
during "heat-up" (approx. 1/2 hour) and extended blower operation during "cool-down" of unit. (approx. 1/2 hour)
OPERATION DURING POWER OUTAGES
The stove is designed to operate during power outages.
EXTERIOR VENT LOCATIONS AND RESTRICTIONS