MENDOTA "SEABROOK"
DIRECT VENT
GAS FIREPLACE INSERT
Model D-30 Flat or Bay
(Bay unit not shown)
INSTALLATION & OPERATING INSTRUCTIONS
NO.0109
WARNING: THIS APPLIANCE TO BE USED ONLY AS AN INSERT IN
SOLID FUEL BURNING FIREPLACES.
AVERTISSEMENT: Cet appareil a etre employe seulment comme un inserer dans
lecarburant solide brulant des cheminees.
NOTE:
F
OR INSTALLATION AS A NATURAL VENT
(B-V
ENT
)
INSERT
,
SEE
P
AGE
13.
ORDER THE
4”
N
ATURAL
V
ENT
K
IT FOR
S
INGLE
F
LEX
L
INER
(#AA-11-388).
FOR YOUR SAFETY: DO NOT STORE OR USE GASOLINE OR OTHER
FLAMMABLE VAPORS AND LIQUIDS IN THE VICINITY OF THIS OR ANY
OTHER APPLIANCE.
POUR VOTRE Sécurité: Ne pas entreposer ni utiliser d’essence ni d’autre vaperures ou li-
quides inflammables dans le voisinage de cet appareil ou de tout autre appareil.
FOR YOUR SAFETY: WHAT TO DO IF YOU SMELL GAS:
1. OPEN WINDOWS.
2. DON'T TOUCH ELECTRICAL SWITCHES.
3. DO NOT USE ANY PHONE IN YOUR BUILDING
4. EXTINGUISH ANY OPEN FLAME
5. IMMEDIATELY CALL YOUR GAS SUPPLIER FROM A NEIGHBOR'S
PHONE.
6. FOLLOW THE GAS SUPPLIERS INSTRUCTIONS.
7. IF GAS SUPPLIER IS UNAVAILABLE, CALL YOUR FIRE DEPARTMENT.
POUR VOTRE Sécurité:
Que faire si vous sentez une odeur de gaz:
1. Ne pas tenter d’allumer d’appareil
2. Ne touchez à aucun interrupteur. Ne pas vous servir des télé phones se trouvant dans le
batiment ou vous vous trouvez.
3. Evacuez la pièce, le bâtiment ou la zone.
4. Appelez immédiatement votre fournisseur de gaz depuis un voisin. Suivez les instructions du
fournisser.
5. Si vous ne pouvez rejoindre le fournisseur de gas, appelez le service dos incendies.
WARNING: IMPROPER INSTALLATION, ADJUSTMENT, ALTERATION,
SERVICE OR MAINTENANCE CAN CAUSE INJURY OR PROPERTY
DAMAGE. REFER TO THIS MANUAL. FOR ASSISTANCE OR
ADDITIONAL INFORMATION, CONSULT A QUALIFIED INSTALLER,
SERVICE AGENCY, OR THE GAS SUPPLIER.
AVERTISSEMENT: Une installation, un réglage, une modification, un entretien ou une main-
tenance incorrects peuvent entrainer des dommages matériels, des lésions corporelles ou la perte
de vies humaines. Consuter le manuel des usagers fourn avec ce generateur d’air chaud.
MISE EN GARDE: Installation, réglage, modification, entretien ou depannage non appropriés pourront causer des blessures ou des dommages materiels. Réferéz-vous au manuel du
proprietaire fourni avac cet appariel. Pour assistance ou renseignements complémentaires, veuillez consulter un installateur expérimenté, une agence dé depannage/entreitien ou cotre
compagnie gaziére. Pour utilisation avec les portes en verre certifiée l'appareil suelement. Ne pas opérer avec le verriére enlever, craquelure, brise.
Vue de la page 0
1 2 3 4 5 6 ... 38 39

Résumé du contenu

Page 1 - GAS FIREPLACE INSERT

MENDOTA "SEABROOK" DIRECT VENT GAS FIREPLACE INSERT Model D-30 Flat or Bay (Bay unit not shown) INSTALLATION & OPERATING INSTRUCTIONS

Page 2 - SPECIFICATIONS

9 12. Attach a sheet metal strap loop to the flex end of the liner(s) and tie a rope to it. Two installers should pro-ceed to the roof and drop t

Page 3 - ...CAUTION

10 14. TYPICALLY FOR FACTORY BUILT ZC FIREPLACES, REFER TO PAGE 7. Use Mendota Co-Axial Vent Kit -- # AA-11-00378 4"

Page 4 - HEATING PERFORMANCE

11 19. Carefully slide the Insert into place in the fireplace opening. At this time, check that Insert is level and plumb with the fireplace openi

Page 5 - CO-LINEAR VENT ADAPTER

12 21. FINAL VENT BOOT ADAPTER INSTALLATION A. Place u-clamp over threaded rod. Thread clamping nut on threaded rod and tighten firmly. B. R

Page 6 - D-30 Surround Dimensions

13 SIDE VIEWBURNER-AIRBOX ASSEMBLYTHERMO DISKFRONTTHREADED RODU-CLAMP5/16" NUT8503-00555FIBERGLASSSEAL DOUGHNUTMAY BE ROUNDOR RECTANGULARDRAFT H

Page 7 - INSTALLATION INSTRUCTIONS

14 D-30 GRILL INSTALLATION FLAT FRONT BAY FRONT FIGURE 8 ...IMPORTANT... NOTE: INSTALLATION, SERVICING AND REPAIR MUST BE DONE B

Page 8 - FLUE VENTING

15 RAISED HEARTH SPECIFICATIONS In most installations, a 16" non-combustible protector is required in front of the glass surface of the

Page 9

16 GAS SUPPLY REQUIREMENTS CORRECT GAS PRESSURE AND PROPER GAS SUPPLY LINE SIZING IS IMPERATIVE TO THE SUCCESSFUL PERFORMANCE OF YOUR MENDOTA GAS FIR

Page 10

17 GAS PRESSURE REQUIREMENTS A MAJOR CAUSE OF OPERATING PROBLEMS WITH GAS APPLIANCES CAN BE IMPROPER GAS PRESSURE! Such problems as changes in flam

Page 11

18 INSTALLATION CHECK OFF LIST The following check list must be completed prior to initial lighting of the Fireplace Insert, or manufacturer's w

Page 12 - SIDE VIEW

1 NOTE: FOR INSTALLATION AS A NATURAL VENT (B-VENT) INSERT, SEE REPLACEMENT MANUAL INCLUDED WITH THE 4” NATURAL VENT KIT FOR SINGLE FLEX LINER (#AA

Page 13 - 85-03-00509

19 LIGHTING INSTRUCTIONS IMPORTANT: Be sure all items on "LIGHTING CHECK OFF LIST" [Pg. 17] have been completed! CAUTION: If the pilot go

Page 14 - THREADED ROD

LOG INSTALLATION 1. Carefully unpack 6-piece log set and bag of coals. NOTE: Logs are very fragile, handle with care. 2. Before installing glass

Page 15 - D-30 GRILL INSTALLATION

21 LOG INSTALLATION STEP 2 LOG INSTALLATION STEP 3

Page 16 - RAISED HEARTH SPECIFICATIONS

22 LOG INSTALLATION STEP 4 LOG INSTALLATION STEP 5

Page 17 - GAS SUPPLY REQUIREMENTS

23 LOG INSTALLATION STEP 6 LOG INSTALLATION STEP 7

Page 18 - GAS PRESSURE REQUIREMENTS

24 LOG INSTALLATION STEP 8 LOG INSTALLATION STEP 9

Page 19 - LIGHTING CHECK OFF LIST

25 WALL SWITCH, REMOTE CONTROL OR THERMOSTAT OPERATION The Insert comes with an "ON-OFF" Rocker Switch located in the lower right hand corn

Page 20 - LIGHTING INSTRUCTIONS

26 BLOWER OPERATION AND WIRING The D-30 Mendota Gas Inserts are equipped with hot air dual blowers. A 120 volt electrical service must be supplied f

Page 21 - LOG INSTALLATION STEP 1

27 BURNERORIFICE FIGURE 16 BLOWER (S) REMOVAL 1. Refer to FIGURE 16. Disconnect power to fireplace and blowers. 2. Turn main gas sup

Page 22 - LOG INSTALLATION STEP 2

28 CUSTOMER INFORMATION AND TROUBLE-SHOOTING MAXIMUM ALLOWABLE SURFACE TEMPERATURE Mendota Inserts/Fireplaces comply with UL Standards for maximum s

Page 23

2 CONGRATULATIONS! You are the owner of a world class heat producing gas fireplace insert. This elegant, highly efficient insert will be a constan

Page 24

29 TROUBLE SHOOTING MENDOTA GAS FIREPLACE INSERT SYMPTOM PROBABLE CAUSES CORRECTIVE ACTION 1. Thin black coating [soot] forms on viewing glass. A.

Page 25

30 MAINTENANCE 1. ANNUAL MAINTENANCE OF MENDOTA UNITS IS REQUIRED. The following procedures must be per-formed each year by a Mendota approved servi

Page 26 - THERMOCOUPLE

31 REPLACEMENT PARTS LIST MENDOTA GAS FIREPLACE INSERT - MODEL D-30 PART NO. DESCRIPTION PART NO. DESCRIPTION HA-28-00040 Flat Glass Door Assy HA-

Page 27 - BLOWER OPERATION AND WIRING

32 PILOT HOODPILOT ORIFICEUSE 716" WRENCH TO LOOSEN HOODNATURAL TO LP GAS CONVERSION HA-28-00194 This conversion must be made by a qualified serv

Page 28 - FIGURE 16

33 Figure 21LP PRESSURE REGULATORNG PRESSURE REGULATORGAS VALVE BODYSCREWS

Page 29

34 "LABEL REPRESENTATION" LISTED GAS-FIRED DIRECT VENT ROOM HEATER POÊLE AU GAZ HOMOLOGUE’, A AÉRATION DIRECTE MODEL: D-30 CERTIFIED FOR CAN

Page 30

35 MENDOTA WARRANTY QUALIFICATION & SERVICE REFERENCE FORM As a part of Mendota's on-going program of customer satisfaction, this Form verif

Page 31 - MAINTENANCE

36 TAPE SHUT --------------------------------------------------------------------------------------------------------------------

Page 32 - REPLACEMENT PARTS LIST

37 MENDOTA EXTENDED LIFETIME PROTECTION AND LIMITED WARRANTY MENDOTA GAS FIREPLACE INSERT MODEL: D-30 NAT. & L.P. Mendota Division of Johnson Ga

Page 33 - HA-28-00194

Johnson Gas Appliance Company 520 E Avenue N.W. - Cedar Rapids, IA 52405 Website: www.johnsongas.com Part #85-03-00687

Page 34

3 GENERAL INFORMATION Your Mendota Gas Fireplace Insert has a state-of-the-art direct vent, sealed combustion system. This ad-vanced, highly effici

Page 35 - "LABEL REPRESENTATION

4 MENDOTA GAS DIRECT VENT FIREPLACE INSERT SPECIFICATIONS & CLEARANCES OF GRILL20 7/1612" MIN.FROM TOPTO MANTELFRONT VIEW30 1/4BRASS TR

Page 36

5 OF GRILL20 7/1612" MIN.FROM TOPTO MANTELFRONT VIEW30 1/4BRASS TRIMMANTEL DEPTH (WIDTH)30 7/1621 1/8ITEM REMOVABLEFOR INSTALLATION16" MI

Page 37

6 INSTALLATION INSTRUCTIONS CAUTION: Each installation must conform to all local, state and national codes. Refer to the national fuel gas code and

Page 38 - AND LIMITED WARRANTY

7 FLUE VENTING 10. The D-30 Insert must be vented vertically to the outside and must use the Mendota flexible ducting system. There are two method

Page 39

8 AA-11-378 CO-AXIAL VENT KIT AA-11-377 CO-LINEAR VENT KIT NOTE: THE INSERT IS DESIGNED, TESTED & LISTED FOR OPERATION ONLY