Mendota SEABROOK D-30 Instructions d'exploitation Page 2

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 39
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 1
1
NOTE:
F
OR INSTALLATION AS A NATURAL VENT
(B-V
ENT
)
INSERT
,
SEE REPLACEMENT MANUAL
INCLUDED WITH
THE
4”
N
ATURAL
V
ENT
KIT
FOR
SINGLE
FLEX
LINER
(#AA-11-388).
TABLE OF CONTENTS
GENERAL INFORMATION ......................................................................................................................................3
SPECIFICATIONS & CLEARANCES .......................................................................................................................4
INSTALLATION INSTRUCTIONS ...........................................................................................................................6
FLUE VENTING .........................................................................................................................................................7
RAISED HEARTH SPECIFICATIONS .....................................................................................................................15
GAS SUPPLY REQUIREMENTS ..............................................................................................................................16
GAS PRESSURE REQUIREMENTS .........................................................................................................................17
INSTALLATION CHECK OFF LIST ........................................................................................................................18
LIGHTING INSTRUCTIONS .....................................................................................................................................19
LOG INSTALLATION ...............................................................................................................................................20
WALL SWITCH, REMOTE CONTROL OR THERMOSTAT OPERATION ..........................................................25
BLOWER AND WIRING INSTALLATION OPERATION ......................................................................................26
CUSTOMER INFORMATION AND TROUBLE-SHOOTING ................................................................................28
TROUBLE SHOOTING ..............................................................................................................................................29
MAINTENANCE……………………………………………………………………………………………………30
PARTS LIST ................................................................................................................................................................31
NATURAL TO LP CONVERSION ............................................................................................................................32
INTERTEK TESTING GAS LABEL ..........................................................................................................................34
WARRANTY ...............................................................................................................................................................35
SPECIFICATIONS
MODEL D-30
High Fire
- Adjustable to - Low Fire
BTUH. NAT. GAS 30,000 19,900
BTUH. L.P. GAS 29,000 16,200
NOTE: LP CONVERSION KIT #HA-28-00194 MUST BE PURCHASED SEPARATELY. – SEE PG. 28 FOR
INSTALLATION INSTRUCTIONS.
MAIN ORIFICE: #35 NAT., #52 LP
OVERALL EFFICIENCY ..................... EXCEEDS D.O.E. EFFICIENCY REQUIREMENTS (A.F.U.E.)
FLUE VENT LINERS ........................... CO-LINEAR - 4" DIAMETER EXHAUST & 4" DIAMETER INLET or
................................................................ CO-AXIAL - 4" DIAMETER EXHAUST & 6" DIAMETER INLET
TOTAL WEIGHT .................................. 175#
SAFETY ................................................. AGA CERTIFIED PILOT GENERATOR, MILLIVOLT SYSTEM
ACTIVATED WITH SWITCH, REMOTE CONTROL OR THERMOSTAT.
GAS REQUIREMENTS ........................ SUPPLY PRESSURE
: GAS INLET: 3/8" N.P.T.
NAT. GAS: 7" W.C. [5.0" W.C. MIN., 11" W.C. MAX.]
L.P. GAS: 11" W.C. [11" W.C. MIN., 13" W.C. MAX.]
ELECTRICAL REQUIREMENTS ...... 120 VOLT
LISTINGS....INTERTEK TESTING SERVICES TESTED TO: ANSI Z21.11.1-1993 & CAN1-2.1 M89 "GAS-FIRED
VENTED ROOM HEATERS" & CAN/CGA 2.17-M91 "GAS-FIRED APPLIANCES FOR USE AT HIGH ALTITUDES",
ANSI Z21.44-1995 "GAS-DIRECT VENT WALL FURNACES" AND CGA INTERIM REQUIREMENT #41-M91
"DIRECT VENT GAS FIREPLACES" AND UL307B "MOBILE HOME, APPROVED EXCEPT RECREATIONAL
VEHICLES"
Gas appliances must be tested and certified by a nationally recognized testing and certification agency to American National Stan-
dards Institute - ANSI Gas Appliance Safety Standards. For more information see Pg. 34. The Mendota Gas Fireplace Insert has
been tested and certified by Intertek Testing Services. 8431 Murphy Drive, Middleton, WI 53562.
INSERT INCLUDES HEARTHGLO COMBUSTION SYSTEM, DUAL HOT AIR BLOWERS, 6 CERAMIC FIBER LOG MODULE & COALS, NEO-CERAM
GLASS, PIEZO IGNITER AND AGA CERTIFIED SAFETY SYSTEM.
OPTIONS: BLACK OR GOLD PLATED GRILL SETS, BLACK OR GOLD FILIGREE FRONTS, BLACK ARCHED DOOR KITS (ANDOVER), FEDERAL
& CONTEMPORARY TRIM KITS, 3 SIZES OF SURROUNDS & 2 SIZES OF VENTING KITS.